Click Study Flashcards above to open the flashcard hub — hundreds of EPA 608 cards you can flip, match, type, or quiz yourself on. Every card is drawn from the four official exam sections — Core plus Type I, II, and III — so you study exactly what the exam tests.[1] Pair them with our free practice test and study guide.
EPA 608 Flashcard Study Modes
Flip mode lets you page through cards at your own pace and check yourself. Match turns terms and definitions into a timed pairing game. Type shows the definition and asks you to produce the term, so a card like What is R-410A? has to come from memory. Quiz builds multiple-choice questions from the same cards for a quick accuracy read.

Why Flashcards Work for the EPA 608 Exam
Core is the largest block at 88 cards, and it feeds every certification type you might sit for. The cards drill refrigerant identification, atmospheric science, and the handling rules that sit behind the regulations, mixing prompts like What is R-12? and What is R-134a? with policy cards such as What is the AIM Act? and abbreviation checks like the card that asks What does ODP stand for?
Type II — High-Pressure holds 40 cards covering the refrigerants and diagnostics you meet in residential and commercial split systems. Expect refrigerant cards such as What is R-22? and What is R-410A?, measurement fundamentals behind What is superheat? and What is subcooling?, and service logic in the card that asks What confirms a leak repair worked?
Type III — Low-Pressure has 37 cards built around chillers and the vacuum-side behavior that makes them different. You get refrigerant cards like What is R-11? and What is R-123?, equipment questions such as What does a purge unit do? and What is a centrifugal chiller?, plus pressure-reading prompts like the card that asks What does ’mm Hg absolute’ mean?
Type I — Small Appliances rounds out the deck with 35 cards on sealed systems and the recovery methods that apply to them. Hydrocarbon refrigerants show up in What is R-290? and What is R-600a?, scope questions appear in prompts like Is a dehumidifier a small appliance?, and procedure gets covered by What is system-dependent recovery?
The EPA 608 exam is dense with terminology and exact figures — refrigerant classes, the three R’s, recovery percentages, and vacuum levels.[2] Spaced flashcards are the most efficient way to keep it all fresh. Used alongside our practice test and study guide, they turn review time into measurable progress.
EPA 608 Flashcards by Section
The cards are organized by the four official exam sections. Everyone should start with Core, then drill the type section(s) they need — or all three for Universal:[1]
| Section | What it covers |
|---|---|
| Core | Ozone & climate, ODP/GWP, phase-out, venting rule, the three R's, cylinders, safety |
| Type I — Small Appliances | Small-appliance definition, 90%/80% recovery, passive vs active recovery |
| Type II — High-Pressure | R-22/R-410A, recovery vacuum (0/10 in. Hg), 50-lb leak thresholds |
| Type III — Low-Pressure | R-11/R-123 chillers, 25 mm Hg absolute, purge units, rupture disc |
How to Get the Most Out of These Flashcards
- Start with Core. At 88 cards it is the biggest domain and the one every certification type depends on, so weak Core recall will drag down each specialty section.
- Type-drill the refrigerant numbers. Cards like What is R-22? and What is R-123? blur together fast, and typing the term forces you to separate high-pressure from low-pressure families.
- Use Match for the definition pairs. Short abbreviation and equipment cards, the kind behind What does GWP stand for? and What is a reclaimer?, pair quickly and expose the ones you only half know.
- Move to the practice test once Quiz holds steady. When Core and your chosen type both return clean rounds, switch over to sit with full-length questions and the study guide.
- Keep the cadence small. Work one domain per session in blocks rather than running all 200 cards at once, then Flip through missed cards again before the next block.
EPA 608 Flashcards FAQ
Hundreds of free EPA 608 flashcards, organized across all four exam sections — Core plus Type I, Type II, and Type III — covering ozone science, regulations, refrigerant recovery, and the numbers you must memorize. They're free with no account required.
Yes. Flashcards use active recall — retrieving an answer from memory — which research shows is one of the most effective study methods, especially in short, spaced sessions. They're ideal for the exam's heavy load of definitions, refrigerant names, and exact recovery numbers.
All four sections: Core (ozone, regulations, recovery, safety), Type I (small appliances), Type II (high-pressure appliances), and Type III (low-pressure chillers) — including the recover/recycle/reclaim definitions and required recovery levels.
Start with the Core deck — it's required of everyone. Then drill the section(s) you need (or all three for Universal). Mix the modes: flip to learn, type to test recall, match for speed, and quiz to check yourself before a full practice test.
Yes — 100% free, all four study modes, no paywall.
Yes. The cards are organized to the current EPA Section 608 structure — Core plus Type I, II, and III — and reflect current rules, including the venting prohibition and the AIM Act HFC phasedown.
EPA 608 flashcard bank
All 200 cards, by topic
A reference copy of every card in this deck. Each answer stays hidden until you choose to show it. To study with Flip, Match, Type and Quiz modes and track what you have mastered, use Study Flashcards at the top of the page.
Core (88)
- What does ODP stand for?
Show answerHide answer
Ozone Depletion Potential — how much a substance harms stratospheric ozone, relative to CFC-11 (1.0).
- What does GWP stand for?
Show answerHide answer
Global Warming Potential — how much heat a gas traps over time, relative to carbon dioxide (1.0).
- What does CFC stand for?
Show answerHide answer
Chlorofluorocarbon — an early refrigerant (e.g., R-12) with high ozone depletion potential.
- What does HCFC stand for?
Show answerHide answer
Hydrochlorofluorocarbon — a transitional refrigerant (e.g., R-22) with lower ODP than a CFC.
- What does HFC stand for?
Show answerHide answer
Hydrofluorocarbon — a chlorine-free refrigerant (e.g., R-410A) with zero ODP but high GWP.
- What does HFO stand for?
Show answerHide answer
Hydrofluoroolefin — a newer refrigerant (e.g., R-1234yf) with zero ODP and very low GWP.
- What law is Section 608 part of?
Show answerHide answer
The Clean Air Act — the U.S. federal law the EPA uses to regulate refrigerant handling.
- Is venting refrigerant legal?
Show answerHide answer
No. Knowingly venting refrigerant during service, repair, or disposal has been illegal since 1995.
- What is a de minimis release?
Show answerHide answer
A small, unavoidable release of refrigerant during good-faith recovery — not treated as illegal venting.
- What does 'recover' mean?
Show answerHide answer
Remove refrigerant from an appliance and store it in an external container, without cleaning or testing it.
- What does 'recycle' mean?
Show answerHide answer
Clean recovered refrigerant on-site (oil separation, filter-driers) for reuse in the same owner's equipment.
- What does 'reclaim' mean?
Show answerHide answer
Reprocess refrigerant to like-new purity meeting AHRI 700 and verify it chemically — the only refrigerant resold to a new owner.
- Which of the three R's can be resold to a new owner?
Show answerHide answer
Only reclaimed refrigerant — it must meet the AHRI 700 purity standard and be lab-verified.
- What purity standard must reclaimed refrigerant meet?
Show answerHide answer
AHRI 700 — the industry standard for like-new refrigerant purity.
- Who may legally buy regulated refrigerant?
Show answerHide answer
Only technicians certified under Section 608 (or 609 for motor-vehicle AC); the rule now covers most HFCs.
- Does EPA 608 certification expire?
Show answerHide answer
No — it is a one-time, lifetime credential with no renewal or CEUs required.
- Who administers the EPA 608 exam?
Show answerHide answer
EPA-approved certifying organizations (e.g., ESCO Institute, Mainstream Engineering, HVAC Excellence) — not the EPA itself.
- Where is the protective ozone layer located?
Show answerHide answer
In the stratosphere, well above the weather at ground level.
- What does stratospheric ozone protect us from?
Show answerHide answer
Harmful ultraviolet (UV) radiation from the sun.
- What health effects does ozone depletion increase?
Show answerHide answer
Higher rates of skin cancer and cataracts from increased ground-level UV radiation.
- Why can a leaked CFC damage ozone years later?
Show answerHide answer
It is so stable it drifts up to the stratosphere, where UV light eventually frees its chlorine.
- What frees chlorine from a CFC molecule?
Show answerHide answer
Ultraviolet (UV) light in the stratosphere splits the molecule and releases a chlorine atom.
- How does one chlorine atom harm ozone?
Show answerHide answer
It acts as a catalyst, destroying thousands of ozone molecules before it is removed.
- GWP is measured relative to which substance?
Show answerHide answer
Carbon dioxide (CO₂), which is set at a GWP of 1.0.
- ODP is measured relative to which substance?
Show answerHide answer
CFC-11, which is set at an ODP of 1.0.
- Can a refrigerant have zero ODP but high GWP?
Show answerHide answer
Yes — HFCs like R-410A do not deplete ozone but still trap a lot of heat (high GWP).
- What is the Montreal Protocol?
Show answerHide answer
The 1987 international treaty that set the schedule for phasing out ozone-depleting substances.
- When was the Montreal Protocol signed?
Show answerHide answer
1987.
- Why were HCFCs phased out after CFCs?
Show answerHide answer
HCFCs were lower-ODP transitional refrigerants, so CFCs (the worst for ozone) were eliminated first.
- When did R-22 production and import end in the U.S.?
Show answerHide answer
January 1, 2020.
- How can a technician still get R-22 to service old equipment?
Show answerHide answer
By using recovered, recycled, or reclaimed R-22 from existing stock — no new R-22 is produced.
- What is the AIM Act?
Show answerHide answer
The American Innovation and Manufacturing Act of 2020, directing the EPA to phase down high-GWP HFCs.
- What does the AIM Act target — ozone or climate?
Show answerHide answer
Climate (GWP). HFCs have zero ODP, so the AIM Act phases them down for their warming potential.
- By how much does the AIM Act phase down HFCs?
Show answerHide answer
About 85% over 15 years.
- What is the single most important rule of Section 608?
Show answerHide answer
It is illegal to knowingly vent regulated refrigerant during service, maintenance, or disposal.
- Color of a refrigerant recovery cylinder?
Show answerHide answer
Gray body with a yellow top (shoulder).
- Maximum fill of a recovery cylinder?
Show answerHide answer
80% of capacity by weight — liquid refrigerant expands as it warms and can rupture an overfilled cylinder.
- Why must a recovery cylinder never be filled past 80%?
Show answerHide answer
Liquid refrigerant expands as temperature rises; an overfilled cylinder can rupture.
- How often must a recovery cylinder be hydrostatically tested?
Show answerHide answer
Every 5 years (DOT requirement).
- Can disposable refrigerant cylinders be refilled?
Show answerHide answer
No — it is illegal to refill a disposable (one-time-use) cylinder.
- What must be done to a disposable cylinder before disposal?
Show answerHide answer
Evacuate it to a deep vacuum so it is empty before recycling the metal.
- What hazard does refrigerant vapor pose in a confined space?
Show answerHide answer
Asphyxiation — the vapor displaces oxygen; ventilate and use an oxygen-deprivation monitor.
- What injury can liquid refrigerant cause to skin or eyes?
Show answerHide answer
Frostbite — it is extremely cold; wear gloves and eye protection.
- What can happen if refrigerant contacts an open flame?
Show answerHide answer
It can form toxic gases (such as phosgene) — never expose refrigerant to a flame.
- What is a reclaimer?
Show answerHide answer
An EPA-certified facility that reprocesses used refrigerant to AHRI 700 purity for resale.
- What is a halogenated leak detector?
Show answerHide answer
An electronic detector that finds halogen-containing refrigerant leaks (CFCs, HCFCs, HFCs).
- What is the dielectric strength concern with refrigerants?
Show answerHide answer
Some refrigerants conduct or react in ways that matter for electrical safety; follow manufacturer handling rules.
- What recordkeeping is required when disposing of appliances?
Show answerHide answer
Records showing refrigerant was recovered before disposal must be kept per EPA requirements.
- Which Clean Air Act section covers motor-vehicle AC?
Show answerHide answer
Section 609 — Section 608 covers stationary equipment.
- What is a 'substitute' refrigerant under EPA rules?
Show answerHide answer
A non-ozone-depleting refrigerant (often an HFC or HFO) used in place of a CFC or HCFC.
- Does the venting prohibition cover HFCs?
Show answerHide answer
Yes — the prohibition was extended to most HFC substitute refrigerants, not just ozone-depleting ones.
- What is dehydration (evacuation) of a system?
Show answerHide answer
Pulling a deep vacuum to remove moisture and noncondensables before charging.
- What unit is used for deep-vacuum dehydration?
Show answerHide answer
Microns (1 micron = 0.001 mm Hg); about 500 microns is a typical deep-vacuum target.
- What instrument confirms a deep vacuum near 500 microns?
Show answerHide answer
A micron (vacuum) gauge.
- Why remove moisture from a refrigeration system?
Show answerHide answer
Moisture forms acids and ice, causing corrosion, restrictions, and component failure.
- What is an A2L refrigerant?
Show answerHide answer
A mildly flammable, low-toxicity refrigerant class (e.g., many HFOs) used as a low-GWP replacement.
- Why is R-410A's GWP a concern under the AIM Act?
Show answerHide answer
It has a high GWP, so it is being phased down even though it has zero ODP.
- What is virgin refrigerant?
Show answerHide answer
Newly manufactured refrigerant that has never been used, meeting purity specifications.
- What does 'self-contained' recovery equipment mean?
Show answerHide answer
Active recovery gear with its own compressor that can pull refrigerant from an appliance on its own.
- What does 'system-dependent' recovery mean?
Show answerHide answer
Passive recovery that uses the appliance's own compressor or pressure; allowed only on small appliances.
- What is the pressure-temperature (P/T) relationship?
Show answerHide answer
For a given refrigerant, pressure and saturation temperature change together — read with a P/T chart.
- Why must recovery equipment be certified?
Show answerHide answer
To prove it meets EPA performance standards for how much refrigerant it recovers.
- What is a major benefit of recovering refrigerant vs venting?
Show answerHide answer
It prevents ozone depletion and climate impact and conserves valuable refrigerant for reuse.
- What is ozone (chemical formula)?
Show answerHide answer
O₃ — a molecule of three oxygen atoms that, in the stratosphere, absorbs UV radiation.
- What is the troposphere?
Show answerHide answer
The lowest atmospheric layer where weather occurs; ground-level ozone here is a pollutant, not protective.
- Why is ground-level ozone different from stratospheric ozone?
Show answerHide answer
Ground-level ozone is smog (harmful to breathe); stratospheric ozone shields Earth from UV.
- What is R-12?
Show answerHide answer
A common CFC refrigerant (high ODP) once used in refrigerators and car AC; now banned from production.
- What is R-134a?
Show answerHide answer
An HFC refrigerant (zero ODP, high GWP) widely used in refrigeration and older mobile AC.
- What is a blend (zeotropic) refrigerant?
Show answerHide answer
A mix of refrigerants whose components boil at different temperatures, causing temperature glide.
- What is temperature glide?
Show answerHide answer
The temperature range over which a zeotropic blend evaporates or condenses; charge as a liquid.
- Why charge a zeotropic blend as a liquid?
Show answerHide answer
To keep the blend's proportions correct; charging as vapor can fractionate the components.
- What is fractionation of a refrigerant blend?
Show answerHide answer
Separation of a blend's components so the mix no longer matches its spec — avoid by liquid charging.
- What agency enforces Section 608?
Show answerHide answer
The U.S. Environmental Protection Agency (EPA).
- Can you be fined for venting refrigerant?
Show answerHide answer
Yes — illegal venting can result in significant civil penalties under the Clean Air Act.
- What is an EPA-certified recovery machine?
Show answerHide answer
Equipment tested and certified to meet EPA recovery performance standards.
- What is the difference between a CFC and an HCFC?
Show answerHide answer
An HCFC contains hydrogen, making it less stable and lower-ODP than a CFC.
- Why does adding hydrogen lower a refrigerant's ODP?
Show answerHide answer
The hydrogen makes the molecule break down lower in the atmosphere, so less chlorine reaches the ozone layer.
- What is the Significant New Alternatives Policy (SNAP)?
Show answerHide answer
An EPA program that reviews and lists acceptable substitute refrigerants.
- What does it mean if a refrigerant is 'phased out'?
Show answerHide answer
Its production and import are banned on a schedule (e.g., CFCs, then HCFCs).
- What does it mean if a refrigerant is 'phased down'?
Show answerHide answer
Its production/consumption is reduced over time but not fully banned — e.g., HFCs under the AIM Act.
- What PPE protects against liquid-refrigerant frostbite?
Show answerHide answer
Gloves and eye protection (safety glasses or goggles).
- What monitor warns of an oxygen-deficient atmosphere?
Show answerHide answer
An oxygen-deprivation (oxygen) monitor.
- What is a deep vacuum used for besides dehydration?
Show answerHide answer
To verify a system holds vacuum (a leak/standing-vacuum test) and to remove noncondensables.
- What does 'hermetically sealed' mean?
Show answerHide answer
Factory-sealed so the refrigerant circuit is airtight and closed.
- What is an overfill-protection device on a cylinder?
Show answerHide answer
A float or shutoff that prevents filling a recovery cylinder past the safe 80% level.
- Why keep records of recovered refrigerant?
Show answerHide answer
EPA requires recordkeeping to verify proper recovery, recycling, reclamation, and disposal.
- What's the purpose of a filter-drier in recycling?
Show answerHide answer
To remove moisture and contaminants from refrigerant during on-site recycling.
- What is the main goal of the three R's?
Show answerHide answer
To keep refrigerant out of the atmosphere by reusing it rather than venting and replacing it.
Type I — Small Appliances (35)
- What is a 'small appliance' under Section 608?
Show answerHide answer
A product fully manufactured, charged, and hermetically sealed at the factory with 5 lb or less of refrigerant.
- What charge size defines a small appliance?
Show answerHide answer
5 pounds or less of refrigerant.
- Besides 5 lb, what makes a unit a small appliance?
Show answerHide answer
It must be fully manufactured, charged, and hermetically sealed at the factory.
- Is a field-charged unit a small appliance?
Show answerHide answer
No — a field-assembled or field-charged unit is never a small appliance, regardless of charge.
- Give examples of small appliances.
Show answerHide answer
Household refrigerators, freezers, window AC, PTACs, dehumidifiers, water coolers, and vending machines.
- Type I recovery: compressor running?
Show answerHide answer
Recover at least 90% of the charge (post-Nov 15 1993 equipment).
- Type I recovery: compressor not running?
Show answerHide answer
Recover at least 80% of the charge (post-Nov 15 1993 equipment).
- Why is the recovery target higher with the compressor running?
Show answerHide answer
A working compressor helps push refrigerant out, so more (90%) can be recovered.
- What date marks the higher recovery-equipment standards?
Show answerHide answer
November 15, 1993 — the cutoff for the higher post-1993 recovery efficiencies.
- Which equipment allows system-dependent (passive) recovery?
Show answerHide answer
Only small appliances.
- What is system-dependent recovery?
Show answerHide answer
Passive recovery using the appliance's own compressor or internal pressure to push refrigerant out.
- Can passive recovery be used on a large rooftop AC?
Show answerHide answer
No — system-dependent recovery is permitted only on small appliances.
- What is the recovery requirement if you don't know if the compressor works?
Show answerHide answer
Treat it as non-operating: recover at least 80% of the charge.
- Does Type I cover disposal of small appliances?
Show answerHide answer
Yes — Type I covers both servicing and disposal of small appliances.
- Is the Type I exam open-book?
Show answerHide answer
Through some EPA-approved organizations it can be taken open-book and proctored by mail.
- What is a piercing (saddle) valve used for on a small appliance?
Show answerHide answer
To access a sealed system for recovery; it taps into the line for the recovery device.
- What is a passive recovery device's main limitation?
Show answerHide answer
It depends on the appliance's own pressure/compressor, so it works only on small charges (small appliances).
- A small appliance has a seized compressor; you recover 82%. Compliant?
Show answerHide answer
Yes — 80% is the minimum when the compressor is inoperative.
- What refrigerants are common in small appliances?
Show answerHide answer
Historically R-12 and R-134a in refrigerators; R-600a (isobutane) in many newer units.
- What is R-600a?
Show answerHide answer
Isobutane — a low-GWP, mildly flammable hydrocarbon refrigerant used in many small appliances.
- Why handle hydrocarbon refrigerants (R-600a, R-290) carefully?
Show answerHide answer
They are flammable; follow special handling, charge limits, and ignition-source precautions.
- What is R-290?
Show answerHide answer
Propane — a flammable hydrocarbon refrigerant used in some self-contained small appliances.
- Must recovery equipment for small appliances be certified?
Show answerHide answer
Yes — it must meet the recovery standards for post-1993 small-appliance equipment.
- What is a packaged terminal air conditioner (PTAC)?
Show answerHide answer
A self-contained through-the-wall unit (hotels, apartments) that is typically a small appliance.
- What's the recovery rule for a household refrigerator with a running compressor?
Show answerHide answer
Recover at least 90% of the charge.
- Why is a window AC a small appliance but a split AC isn't?
Show answerHide answer
The window unit is factory-sealed and charged; the split system is field-assembled and field-charged.
- What is the recovery requirement label '90/80' shorthand for?
Show answerHide answer
90% recovery with the compressor running, 80% with it not running (small appliances).
- Can a vending machine be a small appliance?
Show answerHide answer
Yes — if it's factory-sealed with 5 lb or less of refrigerant.
- Is a dehumidifier a small appliance?
Show answerHide answer
Yes — typically factory-sealed with a small charge.
- What tool accesses a sealed small-appliance system?
Show answerHide answer
A piercing/saddle (line-tap) valve to connect the recovery device.
- Does Type I allow active (self-contained) recovery too?
Show answerHide answer
Yes — you may use self-contained equipment on small appliances; passive is also allowed only here.
- If a small-appliance compressor works, what % must you recover?
Show answerHide answer
At least 90% of the charge.
- If a small-appliance compressor is dead, what % must you recover?
Show answerHide answer
At least 80% of the charge.
- Why might you recover less when the compressor is off?
Show answerHide answer
Without the compressor's help, the standard is set lower (80%).
- What's a key flammable-refrigerant precaution for small appliances?
Show answerHide answer
Control ignition sources and follow charge limits for R-600a/R-290 hydrocarbon refrigerants.
Type II — High-Pressure (40)
- What does Type II certification cover?
Show answerHide answer
High- and very high-pressure appliances — split AC, heat pumps, and supermarket refrigeration racks.
- Name common high-pressure (Type II) refrigerants.
Show answerHide answer
R-22, R-410A, R-404A, and R-407C.
- What is R-22?
Show answerHide answer
A high-pressure HCFC historically used in residential and commercial AC; production/import ended in 2020.
- What is R-410A?
Show answerHide answer
A very high-pressure HFC that replaced R-22 in modern AC and heat pumps; zero ODP, high GWP.
- How does R-410A's pressure compare to R-22's?
Show answerHide answer
R-410A operates at substantially higher pressures, so tools and recovery gear must be rated for it.
- What is R-404A typically used in?
Show answerHide answer
Commercial and supermarket refrigeration (a high-pressure HFC).
- Type II recovery level for a charge of 200 lb or less?
Show answerHide answer
0 inches of mercury vacuum (atmospheric), with post-1993 equipment.
- Type II recovery level for a charge over 200 lb?
Show answerHide answer
10 inches of mercury vacuum, with post-1993 equipment.
- What charge size changes the Type II recovery vacuum?
Show answerHide answer
200 pounds — above it, the required vacuum increases (to 10 in. Hg with post-1993 gear).
- What unit are Type II recovery levels measured in?
Show answerHide answer
Inches of mercury (in. Hg) vacuum.
- At what charge do leak-repair requirements apply?
Show answerHide answer
Appliances containing 50 pounds or more of refrigerant.
- Leak-repair trigger for comfort-cooling appliances?
Show answerHide answer
An annual leak rate above 10%.
- Leak-repair trigger for commercial refrigeration?
Show answerHide answer
An annual leak rate above 20%.
- Leak-repair trigger for industrial process refrigeration?
Show answerHide answer
An annual leak rate above 30%.
- How soon must a triggering leak generally be repaired?
Show answerHide answer
Within 30 days of discovery (or follow an approved retrofit/retirement plan).
- What confirms a leak repair worked?
Show answerHide answer
A follow-up verification (leak) test confirming the leaks are fixed.
- Why do leak rules target large systems (50+ lb)?
Show answerHide answer
Large charges leaking at high rates release the most refrigerant, so repair is most beneficial.
- What recovery equipment do high-pressure systems require?
Show answerHide answer
Self-contained (active) recovery equipment — not passive recovery.
- What vacuum is used to dehydrate a high-pressure system?
Show answerHide answer
About 500 microns (a deep vacuum), measured with a micron gauge.
- Why dehydrate a system to ~500 microns?
Show answerHide answer
To remove moisture and noncondensables before recharging.
- What is superheat?
Show answerHide answer
The temperature of refrigerant vapor above its saturation temperature — used to check charge.
- What is subcooling?
Show answerHide answer
The temperature of liquid refrigerant below its saturation temperature — used to check charge.
- What is R-407C used for?
Show answerHide answer
As an R-22 retrofit replacement refrigerant (a high-pressure HFC blend).
- Why can't you use R-22 gauges on R-410A?
Show answerHide answer
R-410A's higher operating pressure requires gauges and equipment rated for those pressures.
- What is a high-pressure cutout switch?
Show answerHide answer
A safety control that shuts the system down if discharge pressure rises too high.
- Which Type II number pair matters most for recovery?
Show answerHide answer
200 lb charge cutoff and 0 vs 10 in. Hg vacuum (≤200 lb vs >200 lb, post-1993).
- What is a 'very high-pressure' appliance?
Show answerHide answer
Equipment using refrigerants like R-410A or R-13 that operate at especially high pressures (covered by Type II).
- Can an HFC system trigger leak-repair requirements?
Show answerHide answer
Yes — leak-repair requirements have been extended to substitute refrigerants such as HFCs.
- What is a split-system air conditioner?
Show answerHide answer
A field-installed AC with separate indoor and outdoor units — a Type II high-pressure appliance.
- What is a heat pump?
Show answerHide answer
A reversible AC that heats or cools; high-pressure equipment under Type II.
- Why must a 250-lb system be recovered deeper than a 150-lb one?
Show answerHide answer
Over 200 lb the required vacuum increases (to 10 in. Hg with post-1993 gear).
- Is a 150-lb high-pressure system recovered to 0 or 10 in. Hg?
Show answerHide answer
0 in. Hg — it is at or below the 200-lb cutoff.
- Is a 250-lb high-pressure system recovered to 0 or 10 in. Hg?
Show answerHide answer
10 in. Hg vacuum — it is above the 200-lb cutoff (post-1993 gear).
- Does a 60-lb leaking comfort-cooling system trigger repair?
Show answerHide answer
Yes if it exceeds the 10% annual leak rate (it's over the 50-lb threshold).
- Does a 30-lb system fall under the leak-repair rule?
Show answerHide answer
No — leak-repair requirements apply at 50 lb or more.
- What's the recordkeeping after a major leak repair?
Show answerHide answer
Document the leak rate, repair, and the follow-up verification test.
- Why is R-410A called a 'very high-pressure' refrigerant?
Show answerHide answer
It operates at notably higher pressures than R-22, requiring higher-rated equipment.
- What is a micron gauge used for on a high-pressure system?
Show answerHide answer
To confirm a deep evacuation (about 500 microns) during dehydration.
- What is a P/T (pressure-temperature) chart used for?
Show answerHide answer
To find a refrigerant's saturation temperature at a given pressure when checking charge.
- What is a recovery-only vs recovery/recycle machine?
Show answerHide answer
Recovery-only just removes refrigerant; a recovery/recycle machine also cleans it on-site.
Type III — Low-Pressure (37)
- What does Type III certification cover?
Show answerHide answer
Low-pressure appliances — centrifugal chillers that operate under a vacuum.
- What defines a low-pressure appliance?
Show answerHide answer
It uses a refrigerant that boils below atmospheric pressure, so the low side runs under a vacuum.
- Name common low-pressure (Type III) refrigerants.
Show answerHide answer
R-11 and R-123 (HCFCs), and R-1233zd (a low-GWP HFO replacement).
- What is R-11?
Show answerHide answer
The traditional low-pressure refrigerant in older centrifugal chillers; a CFC, now phased out.
- What is R-123?
Show answerHide answer
The HCFC replacement for R-11 in low-pressure chillers; lower ODP but more toxic.
- What is R-1233zd?
Show answerHide answer
A near-zero-ODP, very-low-GWP HFO refrigerant used in newer low-pressure chillers.
- Type III recovery level (post-1993 equipment)?
Show answerHide answer
25 mm Hg absolute.
- What does 'mm Hg absolute' mean?
Show answerHide answer
A pressure measured from a perfect vacuum — not a reading on a standard vacuum gauge.
- Why is Type III recovery given as 'absolute' not 'vacuum'?
Show answerHide answer
Low-pressure systems run under a vacuum, so the target is set from a perfect vacuum (25 mm Hg absolute).
- In a low-pressure chiller, do leaks let refrigerant out or air in?
Show answerHide answer
Air and moisture leak IN, because the low side operates below atmospheric pressure.
- Why does air leak into a low-pressure chiller?
Show answerHide answer
Its low side is below atmospheric pressure, so higher outside pressure pushes air inward.
- What are noncondensables?
Show answerHide answer
Gases like air and nitrogen that don't condense; they raise condensing pressure and cut efficiency.
- What does a purge unit do?
Show answerHide answer
Removes air and noncondensable gases from a low-pressure chiller while retaining the refrigerant.
- What does excessive purging indicate?
Show answerHide answer
An air leak letting noncondensables into the system — find and fix it.
- Why are high-efficiency purge units preferred?
Show answerHide answer
They release far less refrigerant per unit of air purged than older designs.
- What protects a low-pressure chiller vessel from over-pressure?
Show answerHide answer
A rupture disc, typically set around 15 psig.
- At about what pressure does a low-pressure rupture disc relieve?
Show answerHide answer
Around 15 psig.
- What gas is used to leak-test a low-pressure system?
Show answerHide answer
Dry nitrogen — inert, so it won't form a combustible mixture with the oil.
- Why not use oxygen to pressurize a low-pressure system?
Show answerHide answer
Oxygen can combine with refrigeration oil to form a combustible/explosive mixture.
- Why not pressurize a low-pressure chiller to 30 psig?
Show answerHide answer
It exceeds the ~15 psig rupture disc and would burst the disc.
- Between R-11 and R-123, which has lower ODP?
Show answerHide answer
R-123 has the lower ozone depletion potential.
- What's the safety trade-off with R-123?
Show answerHide answer
Lower ODP than R-11, but higher toxicity — needs ventilation and exposure monitoring.
- What happens when air accumulates in a low-pressure chiller?
Show answerHide answer
It raises condensing pressure and reduces system efficiency.
- What kind of compressor do low-pressure chillers use?
Show answerHide answer
A centrifugal compressor.
- What recovery equipment do low-pressure appliances require?
Show answerHide answer
Self-contained (active) recovery equipment designed for low-pressure work.
- What is a centrifugal chiller?
Show answerHide answer
A large cooling machine using a centrifugal compressor — typically a low-pressure (Type III) appliance.
- Why is R-11 considered low-pressure?
Show answerHide answer
It boils below atmospheric pressure, so the system operates under a vacuum at normal temperatures.
- How do you identify a low-pressure appliance in the field?
Show answerHide answer
Its low side sits in a vacuum during operation (below atmospheric pressure).
- What's the leak concern unique to low-pressure chillers?
Show answerHide answer
Air and moisture leaking IN (not refrigerant leaking out), because of the internal vacuum.
- What pressure unit identifies a Type III recovery question?
Show answerHide answer
'mm Hg absolute' (25 mm Hg) — distinct from Type II's inches of mercury vacuum.
- What's the effect of noncondensables on a chiller?
Show answerHide answer
They raise condensing pressure and lower efficiency.
- What signals an air leak on a low-pressure chiller?
Show answerHide answer
A purge unit running far more frequently than normal.
- Why pressurize with nitrogen below 15 psig when leak-testing?
Show answerHide answer
To stay under the rupture-disc setting and avoid bursting the disc.
- Compared with R-11, is R-123 more or less toxic?
Show answerHide answer
More toxic — it requires greater attention to ventilation and exposure monitoring.
- What replaces R-11/R-123 with near-zero environmental impact?
Show answerHide answer
R-1233zd, a low-GWP, near-zero-ODP HFO.
- What does a rupture disc on a chiller do?
Show answerHide answer
Relieves excess pressure (around 15 psig) to protect the vessel from rupturing.
- Why is oxygen dangerous for pressurizing a chiller?
Show answerHide answer
It can react with the refrigeration oil to form a combustible or explosive mixture.
References
- 1.U.S. Environmental Protection Agency. “Section 608 Technician Certification Requirements.” epa.gov. ↑
- 2.U.S. Environmental Protection Agency. “Refrigerant Recovery and Recycling Equipment Requirements.” epa.gov. ↑
- 3.U.S. Environmental Protection Agency. “Phaseout of Ozone-Depleting Substances.” epa.gov. ↑

Career Employer
Career Employer is the ultimate resource to help you get started working the job of your dreams. We cover topics from general career information, career searching, exam preparation with free study materials, career interviewing, and becoming successful in your career of choice.
All PostsCareer Employer’s Editorial Process
Here at Career Employer, we focus a lot on providing factually accurate information that is always up to date. We strive to provide correct information using strict editorial processes, article editing, and fact-checking for all of the information found on our website. We only utilize trustworthy and relevant resources. To find out more, make sure to read our full editorial process page here.